The database does not start
When to use it
A STARTUP fails, most often right after a parameter change, with errors such as ORA-01078, ORA-00093 or ORA-27037.
Run this
Read the exact error first. Do not retry the startup in a loop.
sqlplus / as sysdba
STARTUP NOMOUNT;
-- If this fails, the problem is in the parameter file (SPFILE)
Recovery procedures on this shelf, all in Administration › Setup scripts › SPFILE recovery:
PASSO_A_PASSO_RECRIAR_SPFILE.sql(Administration › Setup scripts › SPFILE recovery): step by step to recreate the SPFILE.RECRIAR_SPFILE.sql(Administration › Setup scripts › SPFILE recovery): the methods to rebuild a broken SPFILE.RESGATAR_PARAMETROS_SPFILE.sql(Administration › Setup scripts › SPFILE recovery): how to recover the parameter values from an old or corrupted SPFILE.
How to read the output
- ORA-01078 with a second error below it means a parameter value is invalid. The second error names the parameter.
- ORA-27037 means the parameter file could not be read: it is missing, or its location is wrong.
- If
STARTUP NOMOUNTworks butMOUNTfails, the problem is the control files. IfMOUNTworks butOPENfails, it is datafiles or redo. Both are recovery situations.
What to do next
- This is always an immediate escalation. Call a senior DBA before you try a fix.
- While you wait, collect: the exact error text, the last 100 lines of the alert log, and what was changed before the restart.
- Never delete or overwrite the existing SPFILE. Copy it first, even if it is broken.
Risk level
CHANGES THE DATABASE This changes configuration or objects. Run it only with an approved change and a rollback step written down.